Skip to main content
The Time Profiler section tags connections with time labels from the appliance local clock. Access Profiles Time Schedule matches these tags.

Core mechanics

Row gate order

  1. Time Profiles prerequisite tags (profile_find).
  2. Weekday range — always enforced (Sunday = 0 … Saturday = 6).
  3. Match mode — ABSOLUTE timestamp window or ALL RANGES (month + day + minutes-from-midnight).
  4. Add/remove time labels.

Time Profiler — match flow

Weekday active flag is stored but not checked — weekday bounds always apply. Set explicit 0–6 or 1–5 ranges; template default 0 alone matches Sunday only.

Match modes

  • ABSOLUTE — Single start/end timestamp from configured month, day, hour, minute fields.
  • ALL RANGES — Current month, day-of-month, and time-of-day must each fall in inclusive windows.

Examples

Open Configure → Custom Settings → Time Profiler → Time profiles. Row fields are Enabled, Comment, Trace Entry, Month/Day/Weekday/Hour/Minute range, Time match mode, and Added Time profiles.

Time Profiler — Time profiles rows

Business hours

Config: Weekday Mon–Fri, hours 9–17, ALL RANGES, add business-hours.Result: tag present weekdays 09:00–17:59 local time.

Lunch window

Config: Weekday 1–5, hours 12–13, add LUNCH_TIME.Result: Access Profiles can Allow/Deny based on lunch tag.

How to verify

  1. Test inside and outside window with Trace Entry.
  2. Detailed logs time_profiles column.