Keep SafeSquid under service watch
Problem statement
If the SafeSquid service stops and no local watchdog restarts it, web access can fail until an operator notices the outage. In branch sites and lean operations teams, that gap can turn a recoverable process failure into a visible business incident.Client scenario
Use Monit when you need the host to:- detect a stopped SafeSquid service quickly
- restart SafeSquid automatically after local process failure
- confirm the watchdog itself is running after reboot
Key benefits
Monit shortens recovery time for simple service failures and gives administrators a clear local health mechanism. It is most useful for single-node deployments, pilot environments, and branch appliances that need basic self-healing.Prerequisites
Client-side preparations
- Ensure you have shell access with administrative privileges on the SafeSquid host.
- Confirm you can restart SafeSquid safely during a maintenance window if this is a production system.
SafeSquid-side setup
- If you used the SafeSquid Appliance Builder, Monit may already be installed.
- Confirm the SafeSquid init/service commands used on the host are valid before building rules around them.
Setup instructions
Confirm whether Monit already exists
Run:Install Monit when it is missing
Run:Update the Monit configuration
Open the Monit configuration directory and editmonitrc.
Set a polling interval, enable the local web status page if your operational model allows it, and include the directory used for service-specific policies.
Example baseline:
/etc/monit/conf.d/.
Restart Monit after changes
Run:Confirm SafeSquid is under Monit control
Run:Start Monit automatically at boot
Run:Verification and validation
Positive test
Stop SafeSquid intentionally:- the SafeSquid process disappears briefly
- Monit detects the stop condition
- SafeSquid starts again without manual intervention
Negative test
Stop Monit and then stop SafeSquid in a controlled test window. SafeSquid should remain down until you restart it manually. This proves the automatic recovery path depends on Monit actually running.Evidence to retain
- output of
monit status - service status before and after the stop test
- time taken between stop event and service recovery
Troubleshooting guide
SafeSquid does not restart after a stop test
Likely causes:- Monit is not running
- SafeSquid is not defined as a monitored service
- the Monit rule points to the wrong service name or PID file
- run
/etc/init.d/monit status - run
monit status - confirm SafeSquid appears as a monitored object
- start or restart Monit
- correct the SafeSquid service check definition
- rerun the stop test
Monit runs but reports no SafeSquid service
Likely causes:- the include path is missing or wrong
- the service policy file was never created
- inspect
monitrc - verify
include /etc/monit/conf.d/exists - verify a SafeSquid-specific rule exists in the included directory
- restore the include line
- add or correct the SafeSquid monitoring rule
- restart Monit and confirm with
monit status
Monitoring breaks after reboot
Likely causes:- Monit is not enabled at startup
- boot sequencing starts SafeSquid before its monitoring rule is available
- check whether Monit starts automatically after reboot
- confirm both Monit and SafeSquid show expected service state
- run
update-rc.d monit enable - reboot in a maintenance window and validate again